Frame
- Door frames are constructed of pattern grade
genuine mahogany (Swietenia Macrophylla).
- Other suitable species are available for paint, clear
and stain grade applications available.
- Standard jamb thickness is 1-1/8" (28 mm);
head jamb thickness with concealed track is 3 11/6" (78mm); interior sill thickness is 3" (76mm); depth is 5/8" (168 mm); or milled to required project dimensions.
- Door frames are built to +/- 1/16" (1mm) tolerance.
- Frames are manufactured with dado joints and are
glued and screwed for maximum strength.
- Finger jointing is not acceptable.
Door
- Stile and rail doors are constructed of pattern
grade genuine mahogany (Swietenia Macrophylla).
- Other suitable species for paint, clear and
stain grade applications available.
- Doors have 2 3/16" (56mm) thick stave core
construction stiles and rails with book matched 1/4" (6mm) thick face veneers.
- Other door thickness available as required.
- Door widths and heights are built to +/- 1/16"
(1mm) tolerance.
- Standard door corners are coped and dowelled.
- Back to back wood panels with a moisture barrier
in configurations as ordered .
- Custom true divided lites (TDL) and/or simulated
divided lites (SDL) in configurations as ordered.
Adhesive
- All wood door components are bonded with
a water resistant polyvinyl acetate industrial adhesive as manufactured by Kleiberit.
Finish
- Undercoat and topcoat paint systems as
available through Fine Paints of Europe.
- Stain and semitransparent finish coats as
available through the "Sikkens" program.
- Other custom finishes available as required.
|
 |

Hardware
- Standard hardware to be Eclipse e3 as
manufactured by Centor Architectural with a maximum door panel weight of 155 lbs. (70 kg).
- Inward or outward opening applications with
up to sixteen door panels and a maximum door panel weight of up to 260 lbs. (120 kg) available.
- Multiple options for locking hardware available.
- Other folding door systems with different
weight and funtion limitations available.
Weather Stripping
- Q-lon compression gasket by Schlegel at sill,
side, head jamb stop and door meeting rails.
Glazing
- Standard tempered insulated glass units are
3/4" (19mm) thick with a 1/2" (13mm) air space. Other thicknesses available as required.
- Glass options include but are not limited to:
laminated, patterned, wire, spandrel, bent, restoration glass and various Low-E options.
- Standard glass units are dual sealed with
polyisobutylene/polysulfide or silicone and are certified by the IGCC to meet a CBA rating.
- Glass units are blocked in glazing
channel with neoprene setting blocks (70 - 90 durometer hardness).
- Glass units are wet-glazed with a high
performance one part silicone sealant (neutral curing).
- Glazing channel is pressure relief vented
and weeped.
- Glass is retained in glazing channel by an
interior wood stop nailed or screwed in place.
- Other glazing systems available as required.
|